Almost every locker quotation ends with a line like “0.6 mm cold-rolled steel”. It is the single number buyers compare between suppliers, and the single number suppliers are most tempted to stretch. This guide explains what the number changes in practice, where thickness matters most, and how to verify it before you approve a production run.
What the number describes
Furniture steel is measured as sheet thickness before coating. A “0.6 mm” panel is 0.6 mm of cold-rolled steel; once it is powder coated you will measure roughly 0.66–0.69 mm with a micrometer, because the paint film adds around 60–90 microns on each side.
Thin sheet is not automatically bad and thick sheet is not automatically better. What matters is whether the thickness matches the duty the locker will see: a school corridor, a factory changing room and a hospital staff room are three different loads.
Where thickness actually matters
- Doors. The panel people open twenty times a day. Thin doors flex, rattle against the frame and lose their shape at the hinge. This is the first place a buyer notices quality.
- Body sides and back. Less about feel, more about resistance to knocks, trolleys and cleaning equipment.
- Shelves. The weakest point in most lockers. A 0.6 mm shelf carrying 15 kg of workwear will bow; 0.8 mm will not.
- Frames and stiffeners. Folds, returns and welded channels do more for rigidity than extra sheet thickness — which is why a well-formed 0.6 mm locker can feel stiffer than a flat 0.8 mm one.
Typical ranges, and what they suit
| Thickness | Typical use | Trade-off |
|---|---|---|
| 0.5 – 0.6 mm | Light duty: schools, temporary sites, retail back-of-house | Lighter freight, lower cost, more care needed in handling |
| 0.7 – 0.8 mm | General duty: offices, staff changing rooms, clinics | The common middle ground for daily commercial use |
| 0.9 – 1.2 mm | Heavy duty: factories, workshops, military and detention use | Stiffer and longer-lived, but heavier — packing volume and freight rise |
Our own production runs 0.6–1.2 mm cold-rolled steel depending on the model and the duty it is specified for. The important point is that the number is chosen per project, not copied from a catalogue.
How to check it before you approve
- Ask for the spec in writing, per component: door, body, shelf, back panel. A single number for the whole cabinet usually means the door is the stated figure and everything else is thinner.
- Measure with a digital micrometer, not by feel. Take five readings per panel at different points, away from folds and welds.
- Subtract the coating. If the paint is 70 microns, a 0.6 mm panel measures about 0.67 mm. A 0.6 mm claim that measures 0.55 mm is a 0.5 mm panel.
- Weigh a door. Steel is 7.85 kg per square metre per millimetre of thickness. A 1 m² door at 0.6 mm weighs about 4.7 kg before coating; at 0.5 mm it is about 3.9 kg. Shipping documents and a scale settle most arguments.
- Load a shelf. Put 15 kg on the middle shelf for a week and look at it. This tells you more than any certificate.
The freight angle
Going from 0.6 mm to 0.8 mm adds about a third to the steel weight of a locker, which shows up in container weight long before it shows up in volume. If you are loading near a weight limit — common on 20-foot containers — thickness is a freight decision as much as a quality one.
What we would recommend
For most institutional projects, 0.7–0.8 mm on doors and shelves with 0.6 mm body panels is the sensible balance: stiff enough for daily use, light enough to load economically. Specify heavier only where the environment is genuinely rough, and ask for the per-component breakdown so the numbers are comparable between suppliers.
If you want to see how this plays out on a real model, the ST-0110 steel locker is a general-duty reference, and the wood-grain locker range shows the same construction with a different finish.